Click to Zoom
The Series 6500/6600 CruiseMaster is available for most diesel engines rated from 25 hp - 2000 hp. A system consists of two Series K diesel fuel flow sensors to measure feed and return flows and a microprocessor based instrument which calculates and displays net flow rate and total fuel consumption. Features Fits most diesel engines rated from 25 hp to 2000 hp. Single engine models available only. Twin diesels require two separate FloScan systems. Microprocessor based electronics with user adjustable calibration for superior accuracy. Models available with 0-5, 0-10 , 0-20, 0-32, 0-50 and 0-100 GPH scales. Self contained totalizer with permanent LCD display records total fuel consumed to 99,999 gallons. Totalizer is resettable using external SPST panel switch (not supplied). Single engine models show the flow rate of the engine. The totalizer records the total consumption of the engine. Panel mounted instrument fits 3-1/16" opening or optional deck mount. Requires 1 SPST toggle panel switch for resetting fuel totalizer reading. Uses Model 201/231 Series K Diesel Standard Flow Sensors which are designed for feed and return flows in the range of 0.3 - 48 GPH . Standard Flow Sensors incorporate 1/4" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows. Uses Model 233/236 Series K Diesel High Flow Senso rs which are designed for feed and return flows in the range of 30 - 400 GPH. High Flow Sensors incorporate 1" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.
FLOSCAN 6510-BOS-2K FLOWMETER - 6510-BOS-2K

The Series 6500/6600 CruiseMaster is available for most diesel engines rated from 25 hp - 2000 hp. A system consists of two Series K diesel fuel flow sensors to measure feed and return flows and a microprocessor based instrument which calculates and displays net flow rate and total fuel consumption.

Features

Fits most diesel engines rated from 25 hp to 2000 hp. Single engine models available only. Twin diesels require two separate FloScan systems.
Microprocessor based electronics with user adjustable calibration for superior accuracy. Models available with 0-5, 0-10 , 0-20, 0-32, 0-50 and 0-100 GPH scales.
Self contained totalizer with permanent LCD display records total fuel consumed to 99,999 gallons. Totalizer is resettable using external SPST panel switch (not supplied). Single engine models show the flow rate of the engine. The totalizer records the total consumption of the engine.
Panel mounted instrument fits 3-1/16" opening or optional deck mount.
Requires 1 SPST toggle panel switch for resetting fuel totalizer reading.
Uses Model 201/231 Series K Diesel Standard Flow Sensors which are designed for feed and return flows in the range of 0.3 - 48 GPH . Standard Flow Sensors incorporate 1/4" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.
Uses Model 233/236 Series K Diesel High Flow Senso rs which are designed for feed and return flows in the range of 30 - 400 GPH. High Flow Sensors incorporate 1" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.



Partnumber: 6510-BOS-2K


UPC Code: 635495011660
 

FLOSCAN 6510-BOS-2K FLOWMETER - 6510-BOS-2K

  Manufacturer Part#: 6510-BOS-2K
SKU: 106588

The Series 6500/6600 CruiseMaster is available for most diesel engines rated from 25 hp - 2000 hp. A system consists of two Series K diesel fuel flow sensors to measure feed and return flows and a microprocessor based instrument which calculates and displays net flow rate and total fuel consumption. Features Fits most diesel engines rated from 25 hp to 2000 hp. Single engine models available only. Twin diesels require two separate FloScan systems. Microprocessor based electronics with user adjustable calibration for superior accuracy. Models available with 0-5, 0-10 , 0-20, 0-32, 0-50 and 0-100 GPH scales. Self contained totalizer with permanent LCD display records total fuel consumed to 99,999 gallons. Totalizer is resettable using external SPST panel switch (not supplied). Single engine models show the flow rate of the engine. The totalizer records the total consumption of the engine. Panel mounted instrument fits 3-1/16" opening or optional deck mount. Requires 1 SPST toggle panel switch for resetting fuel totalizer reading. Uses Model 201/231 Series K Diesel Standard Flow Sensors which are designed for feed and return flows in the range of 0.3 - 48 GPH . Standard Flow Sensors incorporate 1/4" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows. Uses Model 233/236 Series K Diesel High Flow Senso rs which are designed for feed and return flows in the range of 30 - 400 GPH. High Flow Sensors incorporate 1" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.
Only
$ 492.50
Shipping Info:
click here for estimated shipping
Qty  
Buy Now

get stock alert

Availability
Backordered Back-Ordered
Condition
Brand New Brand New

rewards rewards questions
Earn
591 points
on this purchase
 
FLOSCAN 6510-BOS-2K FLOWMETER - 6510-BOS-2K - 6510-BOS-2K
FLOSCAN INSTRUMENT CO INC.
 
Overview
Specifications
Similar Products
Product Reviews
 

FLOSCAN 6510-BOS-2K FLOWMETER - 6510-BOS-2K

The Series 6500/6600 CruiseMaster is available for most diesel engines rated from 25 hp - 2000 hp. A system consists of two Series K diesel fuel flow sensors to measure feed and return flows and a microprocessor based instrument which calculates and displays net flow rate and total fuel consumption.

Features

Fits most diesel engines rated from 25 hp to 2000 hp. Single engine models available only. Twin diesels require two separate FloScan systems.
Microprocessor based electronics with user adjustable calibration for superior accuracy. Models available with 0-5, 0-10 , 0-20, 0-32, 0-50 and 0-100 GPH scales.
Self contained totalizer with permanent LCD display records total fuel consumed to 99,999 gallons. Totalizer is resettable using external SPST panel switch (not supplied). Single engine models show the flow rate of the engine. The totalizer records the total consumption of the engine.
Panel mounted instrument fits 3-1/16" opening or optional deck mount.
Requires 1 SPST toggle panel switch for resetting fuel totalizer reading.
Uses Model 201/231 Series K Diesel Standard Flow Sensors which are designed for feed and return flows in the range of 0.3 - 48 GPH . Standard Flow Sensors incorporate 1/4" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.
Uses Model 233/236 Series K Diesel High Flow Senso rs which are designed for feed and return flows in the range of 30 - 400 GPH. High Flow Sensors incorporate 1" NPT female inlet and outlet ports with 1 PSI or less pressure drop at rated flows.



Partnumber: 6510-BOS-2K

UPC Code: 635495011660

bizrate Customer Certified Site - Katerno Reviews at Bizrate

At all times, Katerno will use best efforts to maintain its accuracy. However, if at any time the data or images provided are incorrectly priced or below fair market value or availability has substantially changed or image or descriptions contain inaccuracies, Katerno shall not be held responsible or liable, furthermore Katerno reserves the right to reject any orders placed based on this erroneous information.
 
 
       
Shopping
Store Info
Katerno
 
© 2008 - 2018 Katerno.com. All rights reserved.
 
   
Click to close
Katerno Reward Points

Earn Points on every purchase! The more you shop, the more you earn.

Reward Points can be applied toward any future purchase. There are no product restrictions.


Find out more...